| Appearance |
Water-white liquid |
| Composition |
Methylcyclohexane/trimethylpentane mixture |
| Moisture Content, Maximum (ASTM E203-75) |
80 ppm |
| Total Acidity (ASTM D664-81) |
< 0.2 mg KOH/g |
| Chlorine Content |
< 10 ppm |
Copper Corrosion (ASTM D-130) |
<< 1 a |
| Flash Point, Tag Closed Cup (ASTM D-56) |
-7 °C (20 °F) |
| Fire Point (ASTM D-1310) |
-7 °C (20 °F) |
| Autoignition Temperature (ASTM E-659) |
264 °C (507 °F) |
Kinematic Viscosity
at -100 °C
at 0 °C
at 100 °C
|
19.0 mm2/s (cSt)
1.14 mm2/s (cSt)
0.41 mm2/s (cSt)
|
| Liquid Density at 25 °C |
743.3 kg/m3 (6.20 lb/gal) |
| Vapor Density at 25 °C |
0.2845 kg/m3 (0.01776 lb/ft3) |
| Coefficient of Thermal Expansion at 100 °C |
0.00142/°C (0.000786/°F) |
| Average Molecular Weight |
102 |
| Cloud Point |
-135 °C (-211 °F) |
| Pumpability, at 300 mm2/s |
-126 °C (-195 °F) |
Minimum Temperatures for Fully Developed Turbulent Flow, (Re = 10000)
10 ft/sec, 1-in tube (3.048 m/s, 2.54-cm tube)
20 ft/sec, 1-in tube (6.096 m/s, 2.54-cm tube)
|
-76 °C (-106 °F)
-93 °C (-135 °F)
|
Minimum Temperatures for Transition Region Flow, (Re = 2000)
10 ft/sec, 1-in tube (3.048 m/s, 2.54-cm tube)
20 ft/sec, 1-in tube (6.096 m/s, 2.54-cm tube)
|
-108 °C (-163 °F)
-118 °C (-180 °F)
|
| Normal Boiling Point |
99.2 °C (210.6 °F) |
| Heat of Vaporization at Maximum Use Temperature of 175 °C (350 °F) |
252.3 kJ/kg (108.6 Btu/lb) |
| Optimum Use Range |
-115 ° to 175 °C (-175 ° to 350 °F) |
| Maximum Bulk Temperature |
175 °C (350 °F) |
| Maximum Film Temperature |
210 °C (410 °F) |
| Pseudocritical Temperature |
299 °C (570.2 °F) |
| Pseudocritical Pressure |
35.0 bar (521.7 psia) |
| Pseudocritical Density |
267.8 kg/m3 (16.72 lb/ft3) |
*Patent Pending.
NOTICE: Although the information and recommendations set forth herein (hereinafter "Information") are presented in good faith and believed to be correct as of the date hereof, Solutia makes no representations or warranties as to the completeness or accuracy thereof. Information is supplied upon the condition that the persons receiving same will make their own determination as to its suitability for their purposes prior to use. In no event will Solutia be responsible for damages of any nature whatsoever resulting from the use of or reliance upon Information or the product to which Information refers. Nothing contained herein is to be construed as a recommendation to use any product, process, equipment or formulation in conflict with any patent, and Solutia makes no representation or warranty, express or implied, that the use thereof will not infringe any patent.