Therminol XP Heat Transfer Fluid
|

Product Bulletin
|
|
|
|
|
Therminol XP heat transfer
fluid is an extremely pure white mineral oil which provides reliable heat transfer at
temperatures from -20° C to 315° C.
Performance features of Therminol XP include:
|
- Low Fouling - The chemical composition of
Therminol XP has been carefully selected to minimize system fouling resulting from
oxidation and degradation of the fluid.
- Practically Non-Toxic - As an indicator of purity, Therminol XP meets
FDA specifications defined in 21 CFR 172.878 and requirements of United States
Pharmacopeia (USP) and National Formulary (NF).
- Thermal Stability - Therminol XP is stable to 315°C.
Users can expect many years of reliable, trouble-free operation, even when operating
continuously at the recommended maximum temperature of 315° C.
- Environmentally Friendly - Therminol XP has outstanding regulatory
status for those seeking heat transfer fluids which have minimum environmental reporting
requirements.

Therminol XP is used in a wide variety of industries, such as:
- Specialty Chemicals
- Laundries
- Food and beverage
- Biodiesel
For more information on Therminol
XP systems and applications
e-mail us or contact your
local sales representative.

Click here to download the product bulletin containing detailed physical and transport properties for Therminol XP.

Therminol®XP
Heat Transfer Fluid
Operating Range -20°C to 315°C (0°F to 600°F)
| Appearance |
Colorless, odorless liquid |
| Composition |
White mineral oil, USP/NF |
| Flash Point (ASTM D-92) |
199°C (390°F) |
| Fire Point (ASTM D-92) |
232°C (450°F) |
| Autoignition Temperature (ASTM E-659) |
346°C (655°F) |
| Kinematic Viscosity, at 40°C |
23.7 mm2/s (cSt) |
| Kinematic Viscosity, at 100°C |
4.06 mm2/s (cSt) |
| Density at 25°C |
875 kg/m3 (7.30 lb/gal) |
| Specific Gravity (60°F/60°F) |
0.882 |
| Coefficient of Thermal Expansion at 200°C |
0.000892/°C (0.000495/°F) |
| Average Molecular Weight |
350 |
| Pour Point |
-29°C (-20°F) |
| Pumpability, at 2000 mm2/s (cSt) |
-20°C (-4°F) |
| Pumpability, at 300 mm2/s (cSt) |
-1°C (30°F) |
| Minimum Temperatures for |
|
Fully Developed Turbulent Flow (Re = 10000)
|
10 ft/sec, 1-in tube
|
72°C (162°F) |
20 ft/sec, 1-in tube
|
51°C (123°F) |
Transition Region Flow (Re=2000)
|
10 ft/sec, 1-in tube
|
30°C (85°F) |
20 ft/sec, 1-in tube
|
17°C (63°F) |
| Boiling Range, 10% |
332°C (630°F) |
| Boiling Range, 90% |
416°C (780°F) |
| Normal Boiling Point |
358°C (676°F) |
| Heat of Vaporization at Max. Use Temp 315°C |
214 kJ/kg (91.9 Btu/lb) |
| Optimum Use Range |
-20°C to 315°C (0-600°F) |
| Maximum Film Temperature |
330°C (625°F) |
| Pseudocritical Temperature |
542°C (1007°F) |
| Pseudocritical Pressure |
15.2 bar (220 psia) |
| Pseudocritical Density |
280 kg/m3 (17.5 lb/ft3) |
NOTICE: Although the information and recommendations set forth herein (hereinafter "Information") are presented in good faith and believed to be correct as of the date hereof, Solutia makes no representations or warranties as to the completeness or accuracy thereof. Information is supplied upon the condition that the persons receiving same will make their own determination as to its suitability for their purposes prior to use. In no event will Solutia be responsible for damages of any nature whatsoever resulting from the use of or reliance upon Information or the product to which Information refers. Nothing contained herein is to be construed as a recommendation to use any product, process, equipment or formulation in conflict with any patent, and Solutia makes no representation or warranty, express or implied, that the use thereof will not infringe any patent.
NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESS OR IMPLIED, OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR OF ANY OTHER NATURE ARE MADE HEREUNDER WITH RESPECT TO INFORMATION OR THE PRODUCT TO WHICH INFORMATION REFERS.
Therminol® is a registered trademark of Solutia Inc.
|