Therminol - Heat transfer fluids   Products
ProductsTherminol TLC Total Lifecycle Care ProgramTherminol Heat Transfer Systems NewsAsk usHeat Transfer Systems Tools and LiteratureTherminol Heat Transfer Fluid Support ContactsTherminol Heat Transfer Systems LinksHeat Transfer Fluid Sample AnalysisTherminol Heat Transfer Fluid Reference DiskMSDS
 
myTherminol web site for reviewing sample data
North America
Therminol 55 | Therminol 59 | Therminol 62 | Therminol 66 | Therminol 72 | Therminol 75 | Therminol VP-1 | Therminol VP-3 | Therminol LT | Therminol D-12 | Therminol VLT | Therminol XP | Therminol FF

Therminol FF
Flush Fluid



Product Bulletin

Get Acrobat

Product Description
Therminol FF is the first synthetic flushing fluid for liquid phase heat transfer systems. Deposits from oxidized, thermally degraded or contaminated fluid can foul interior surfaces, making it necessary to clean the system prior to charging with new fluid. Performance features of Therminol FF include:

  • Fast and Easy - Using Therminol FF to flush your fouled system is faster than chemical cleaning and requires less downtime. This is because you simply drain the old fluid, add Therminol FF and circulate, drain and re-fill with your new heat transfer fluid.
  • Less Costly - Therminol FF is a key component of a low cost alternative to chemically cleaning a heat transfer system containing severely degraded or contaminated organic heat transfer fluid. Solutia can supply Therminol FF and then take it back after it is used at no additional cost. Our cradle-to-grave approach eliminates expensive disposal costs.
  • Compatible With New Fluid - Therminol FF is compatible and miscible with most organic heat transfer fluids, which means less downtime is required for system cleaning.
  • Safe - Therminol FF is a synthetic hydrocarbon with a high flash point and high initial boiling point, making it much safer to use than other cleaning solvents.
  • Technical Service and Support - To help you decide on the correct clean-out procedure, your Therminol specialist can help you develop the necessary parameters required to maximize the effectiveness of the flushing process.

Contact your local sales representative or e-mail for more information.



Detailed Properties
Click here to download the product bulletin containing detailed physical and transport properties for Therminol FF.

Typical Properties

Therminol® FF
Flush Fluid

Appearance Dark amber liquid
Composition Synthetic hydrocarbon
Moisture Content 200ppm
Flash Point (ASTM D-92) >250°F (120° C)
Fire Point (ASTM D-92) >270°F (130° C)
Boiling Range (ASTM D20) 420°F - 550°F (215°C - 287°C)
Viscosity, at 25 °C 2-5 cSt
Density at 25°C 0.96 - 0.98 g/cm3

NOTICE: Although the information and recommendations set forth herein (hereinafter "Information") are presented in good faith and believed to be correct as of the date hereof, Solutia makes no representations or warranties as to the completeness or accuracy thereof. Information is supplied upon the condition that the persons receiving same will make their own determination as to its suitability for their purposes prior to use. In no event will Solutia be responsible for damages of any nature whatsoever resulting from the use of or reliance upon Information or the product to which Information refers. Nothing contained herein is to be construed as a recommendation to use any product, process, equipment or formulation in conflict with any patent, and Solutia makes no representation or warranty, express or implied, that the use thereof will not infringe any patent.

NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESS OR IMPLIED, OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR OF ANY OTHER NATURE ARE MADE HEREUNDER WITH RESPECT TO INFORMATION OR THE PRODUCT TO WHICH INFORMATION REFERS.

Therminol® is a registered trademark of Solutia Inc.

Search By:
    
   Solutia Inc.


  © 2008 Solutia Inc. All rights reserved. Contact Us | Legal | Privacy | Solutia Overview | Site Map
* As used herein, ® denotes registered trademark status in the U.S. only; registration status in other geographies may be different.

North America
Europe/Africa/MiddleEast/CIS
Latin America - Spanish
Latin America - Portuguese
Asia/Pacific
Sample Analysis
Technical Services Hotline
System Design Consultation
Operational Training
Start Up Assistance
Flush Fluid and Fluid Refill
Trade-In Program
Company Highlights
Case Studies
New Product Announcements
Press Releases
Articles/Papers
Current Advertisements
HTC Calculator Spreadsheet
Pipe Insulation Calculator
Codes and Standards Service
Units Conversion Utility
Systems Design Data
Selection Guide
Liquid Phase Design Guide
Vapor Phase Design Guide
Information Bulletins
Therminol Reference Disk
Equipment Manufacturer's List
Sales/Tech Service Personnel
Worldwide Locations
Request Information
Educational Resources
Information Updates
Make a Suggestion
Order Literature
Q & A
North America
Europe/Africa/MiddleEast/CIS
Latin America - Spanish
Latin America - Portuguese
Asia/Pacific